ข้ามไปที่เนื้อหาหลัก

บทความ

กำลังแสดงโพสต์จาก เมษายน, 2017

GRBL Error List

Code Message Description 1 Expected command letter G-code words consist of a letter and a value. Letter was not found. 2 Bad number format Missing the expected G-code word value or numeric value format is not valid. 3 Invalid statement Grbl '$' system command was not recognized or supported. 4 Value < 0 Negative value received for an expected positive value. 5 Setting disabled Homing cycle failure. Homing is not enabled via settings. 6 Value < 3 usec Minimum step pulse time must be greater than 3usec. 7 EEPROM read fail. Using defaults An EEPROM read failed. Auto-restoring affected EEPROM to default values. 8 Not idle Grbl '$' command cannot be used unless Grbl is IDLE. Ensures smooth operation during a job. 9 G-code lock G-code commands are locked out during alarm or jog state. 10 Homing not enabled Soft limits cannot be enabled without homing also enabled. 11 Line overflow Max characters per line exceeded. Received command line was not executed. 12 Step rate ...